New C11 gas target

made on Jan /2007 at University Of buffalo.

many feature were though to bring the best yield while low maintenance as possible.

if any maintenance shall be quick to reduce the body dose exposure.

a micro controller and software was also developed to conduct the load and dump radio active gas to the hotcell. LAB.

 

c11trg_assemblycutview.jpg (71614 bytes) Cut View of NEMO C11 target, water cooled body, isolation foil is Helium cooled.

c11trg_assembly_open.jpg (58168 bytes) Only two clamps will open or seals the target for quick foils replacement.

DSC09436sm.jpg (226121 bytes) Over view of target and controller assembly. note: custom made Peek connector.

 DSC09437sm.jpg (73013 bytes) Typical scenario of target opened.

C11Software.JPG (74745 bytes) C11 Software capable to operate at remote Labs Via DDE protocol.

Target Properties :

internal Chamber Volume: 1.88L

Current rating from 20-40uA

energy 19-22Mev

yield C11 after 1 hours bombardment: 4Ci

target initial pressure 300Psi

target Pressure under Beam 650Psi max.

TRG Foil Al degrade Thickness 0.015-0.020"

Vacuum Al Foil : tron side 25um.

Project designer: Erol Bars

Project associate : Mike Haka, Steve Toorongian

The system is available commercially,  please Contact Fred Covelli or my Self.

Back to to Beam Line Project at the Nuclear medicine Dep at University of Buffalo

Erol Bars
Director Cyclotron Dep. Facility
The State of University of Buffalo, NY
Department of Nuclear Medicine
Center for Positron Emission Tomography

since 2/28/2005