New C11 gas target
made on Jan /2007 at University Of buffalo.
many feature were though to bring the best yield while low maintenance as possible.
if any maintenance shall be quick to reduce the body dose exposure.
a micro controller and software was also developed to conduct the load and dump radio active gas to the hotcell. LAB.
Cut View of NEMO C11 target, water cooled body, isolation foil is Helium
cooled.
Only two clamps will open or seals the target for quick foils replacement.
Over view
of target and controller assembly. note: custom made Peek connector.
Typical
scenario of target opened.
C11
Software capable to operate at remote Labs Via DDE protocol.
Target Properties :
internal Chamber Volume: 1.88L
Current rating from 20-40uA
energy 19-22Mev
yield C11 after 1 hours bombardment: 4Ci
target initial pressure 300Psi
target Pressure under Beam 650Psi max.
TRG Foil Al degrade Thickness 0.015-0.020"
Vacuum Al Foil : tron side 25um.
Project designer: Erol Bars
Project associate : Mike Haka, Steve Toorongian
The system is available commercially, please Contact Fred Covelli or my Self.
Back to to Beam Line Project at the Nuclear medicine Dep at University of Buffalo
Erol Bars
Director Cyclotron Dep. Facility
The State of University of Buffalo, NY
Department of Nuclear Medicine
Center for Positron Emission Tomography
since 2/28/2005
Phone 716 838-5889
Fax 716-838-4918